HB Logo  
Panasonic Communication Systems
KX-TA Digital Hybrid IP-PBX System
Capacities Chart #5
         
       
 
Panasonic Logo
 
       
Bottom of page
     
KX-TDA50 Capacities Chart #5
 
Maximum Number/Cabinet
TDA50
with included
AC Adapter
TDA50
with optional
AC Adapter
Trunk & Extension
   
 
Trunk Port
8
8
 
Analog Port
8
8
Extension Port
28
28
 
Single Line Telephone
24
24
Analog Proprietary
Telephone and DSS Console
44
24
Digital Proprietary
Telephone (Type 1)3
24/48 DXDP
24
Digital Proprietary
Telephone (Type2)2
44
24
Cell Station (KX-TD0141)
44
8
Voice Processing
System
4 (1 System)
4 (1 System)
Wireless Telephone (KX-TD7680 and KX-TD7690)
28
28
Doorphones (KX-T30865, KX-T7775 or Compatable)
4
4
1 Optional Ac Power Supply KX-A236 required to accommodate this Configuration
2 Type 2: T7200 and T7400 Series
3 Type 1: T7600 Series
4 Limited to 8 Max DPT (Type2) + APT + CS
         
                           
 
KX-TDA 50 / 100 / 200 MENORY EXPANSION CARD REQUIREMENTS #6
The Memory card (KX-TDA5105) for the KX-TDA50 and the memory expansion card (KX-TDA0105) for the KX-TDA 100 / 200 is
required when the following features are used
4 Party Conference with Broadcasting
Always Required
DXDP Expanded Capacity
 
Not Required
Required
KX-TDA200
Up to 126 Ports
* From 129 to 256 Ports
KX-TDA100
Up to 64 Ports
** From 65 to 128 Ports
KX-TDA50
Up to 24 Ports
*** From 24 to 48 Ports
* Requires a L type power supply (KX-TDA0103)

** Requires a M type power supply (KX-TDA0104)

*** Requires optional powersupply (KX-A236)
 
       
                           
 
KX-TDA50 MEMORY EXPANSION (MEC) CARD CHART #6A
Model Type


(A)
Number
Equipped
(B)
Value


(A x B)
Total Value
Equpped
Telephone Equipment
   KX-T7600, DSS  
1
 
   KX-T7400, KX-T7200, DSS  
1
 
   KX-T7700, KX-T7300, KX-T7000, DSS  
1
 
Extension Cards
   KX-TDA50 Bulit in 4 Port Super Hybrid Card  
4
 
   KX-TDA5173  
4
 
   KX-TDA5174  
8
 
   Cell Station KX-T0141  
0
 
   Voice Processing System (1 Port 2 CH)  
1
 
                                                                                                                                                                                  Grand Total  
If the grand total point value is 29 or above you will require the optional KX-TDA5105 MEC Card.
   
         
                           
 
KX-TDA50 OPTIONAL AC ADAPTOR KX-A236 Chart #5A
Model Type
(A)
Number
Equipped
(B)
Load Value
(A x B)
Total Value
Equpped
Telephone Equipment
   KX-T7600, DSS  
0
 
   KX-T7400, KX-T7200, DSS  
4
 
   KX-T7700, KX-T7300, KX-T7000, DSS  
4
 
Extension Cards
   KX-TDA50 Bulit in 4 Port Super Hybrid Card  
4
 
   KX-TDA5173  
4
 
   KX-TDA5174  
8
 
   Cell Station KX-T0141  
4
 
   Voice Processing System (1 Port 2 CH)  
0
 
                                                                                                                                                                                  Grand Total  
If the grand total point value is 33 or above you will require the optional KX-A236 AC adaptor
     
           
 
KX-TDA 50 / 100 / 200 SYSTEM SPECIFICATIONS CHART #10
   
Switching:                                                                                                   Non Blocking Distributed Time Switch
Power Source:                                                                                            AC 120v 60Hz
Wiring:                                                                                                        SLT: One Pair (T,R)
                                                                                                                    DPT: One Pair (D1,D2) Or 2 Pair (T,R,D1,D2)
                                                                                                                    APT: 2 Pair (T,R,D1,D2)
                                                                                                                    DSS: One Pair (D1,D2)
Certification No:                                                        TDA100/200           ACJMF03AKX-TDA100
                                                                                    TDA50                    ACJMF03AKX-TDA-50
Ringer Equivaience No:                                                                             0.3A
Facility Interface Code:                                                                             02LS2, 04DU9, BN/DN/1KN/1SN, METALLIC
Service Order Corde:                                                                                 9.0F, 6.0P
Dimensions:
     KX-TDA50............................................................................................(10-3/4 in x 4-3/4 in x 4-5/8 in)
     KX-TDA100..........................................................................................(13-1/3 in x 15-3/5 in x 10-4/5 in)
     KX-TDA200..........................................................................................(17-1/5 in x 16-3/5 in x 10-4/5 in)
Operating Environment:
   Temperature............................................................................................0 °C to 40 °C (32 °F to 104 °F)
   Humidity..................................................................................................10% to 90%  (non condensing)
Consumption
     KX-TDA50 with Main PS.....................................................................(100 V AC to 240 V AC, 1.5 A, 50 Hz/60 Hz)
     KX-TDA50 with Main + Optional PS...................................................(100 V AC to 240 V AC, 3.0 A, 50 Hz/60 Hz)
     KX-TDA100 with Main PSU-M...........................................................(210 W, 2.2 A (at 120 V AC, 60 Hz)
     KX-TDA200 with PSU-M.....................................................................(240 W, 2.5 A (at 120 V AC, 60 Hz)
     KX-TDA200 with PSU-M.....................................................................(490 W, 5.1 A (at 120 V AC, 60 Hz)
 
 
   
 
 
 
   
   
       
HB DISTRIBUTORS 2005/6 ©
All Trademarks Belong to Their Respective Companies. All Prices and Manufacturer's Specifications are Subject to Change Without Notice, Daily.
All rights reserved. HB Distributors can not be responsible for misinformation, typographical errrors. Art work not to scale.